Close

Air dry moisture content (2A1)

This method is required to adjust soil chemical results based on air-dry samples to an oven-dry (105oC)
basis. When the air-dry moisture content (M%) is known, the correction from air-dry
to oven-dry is as follows:

 

            Oven-dry result  =   [Air-dry result  x  (100+ M%)]/100